40+ jaar expertise in laboratoriumapparatuur
Service & onderhoud door gecertificeerde specialisten
Poly Temp Scientific
Refrigerators and freezers 7 April 2026 2 min read

Cleanroom laboratory freezer: ISO Class 6 suitability for TSX HPLRF (23–50 cu ft)

Cleanroom cold storage needs controlled airflow and low particle impact. Therefore, verified test evidence matters. This article explains how representative testing supports a full equipment family.

PT
Poly Temp editorial
Laboratory equipment specialists
Share:

Cleanroom compatible freezers and ISO 14644-14

Cleanroom compatible freezers should align with ISO 14644-14 requirements for equipment suitability. Therefore, a representative TSX unit was selected for third-party environmental testing. Next, the TSX2330FD was tested to ISO 14644-14, focused on airborne particle cleanliness. As a result, the outcome supports the wider engineering family described as “TSX 2330 -30 Freezer”. Moreover, the scope is clearly limited to particle cleanliness, linked to ISO 14644-1 classification.

Cleanroom compatible freezers: ISO Class 6 and EU GMP Grade A

Based on the results, multiple TSX and Cardinal Premier Plus models are declared suitable. The statement specifies ISO Class 6.0 “In Operation” for 0.1 μm to 5.0 μm. In addition, it mentions EU GMP Grade A compatibility with appropriate pre-install preparation. Therefore, you should plan installation steps and preparation routines early. Next, service and maintenance supports consistent performance under real cleanroom conditions.

One airflow concept across sizes, temperatures, and voltages

The declaration covers four unit sizes and four operating temperatures within the portfolio. These temperatures are +4°C, +5°C, -20°C, and -30°C, with no significant design differences affecting cleanroom compatibility. Moreover, the sizes are 23, 30, 45, and 50 cu ft, with five voltage options. Therefore, the evaluation considered moving parts that could create particles and airflow that could drive particles outward. The only moving part outside the refrigerated compartment that interacts with the environment is a cooling fan. Next, air is pulled through the condenser and exits via vent holes at the top. As a result, airflow direction, fan size, and fan speed remain consistent across models, including voltage variants.

Practical guidance for controlled environments

Start by matching temperature range and capacity to your sample workflow. Therefore, the compressor deck area matters, because it is where active airflow is present. Moreover, the declaration notes the compressor deck size is identical across 23 to 50 cu ft housings. Next, connect this information to your risk assessment and cleanroom classification strategy. As a result, cleanroom compatible freezers selection becomes easier to defend during qualification and audits. Finally, preventive maintenance supports long-term stability, alongside laboratory freezers, the brand page Thermo Scientific, and laboratory refrigerators.

00