Our specialists are happy to help with personal advice.
Schedule a consultation +31 515 575 105Cryo tools and protection from Thermo Scientific for working safely with liquid nitrogen (LN2): trolleys and roller bases for LN2 cylinders, transfer hoses and phase separators, cryo tongs such as the CT-300, cryo gloves and aprons, cryo vials and Locator retrieval tools. Poly Temp Scientific supplies everything with advice, installation and maintenance throughout the Netherlands.
Showing 1–20 of 32 results



















Cryo tools and protection are the equipment and personal protective equipment you need to work safely with liquid nitrogen (LN2) and cryogenic storage. Liquid nitrogen has a temperature of about minus 196 degrees Celsius, so unprotected contact causes serious cold injuries within seconds. This category brings together everything you need to move, fill and handle samples, vials and LN2 safely: from trolleys and roller bases for LN2 cylinders to cryo tongs, cryo gloves, aprons and retrieval tools. In this category you will find the cryo tools and protection from Thermo Scientific, supplied with advice, installation and maintenance by Poly Temp Scientific.
Liquid nitrogen carries three risks that you manage with the right tools and protection. First, extreme cold: direct contact with LN2 or with chilled metal causes freezing of the skin and eyes. Second, splashing: when pouring or filling, LN2 can splash, which makes a splash screen, face protection and an apron necessary. Third, oxygen displacement: evaporating nitrogen can lower the oxygen level in an enclosed space, so good ventilation and monitoring are important.
The right tools also keep you away from the cold. With a pair of cryo tongs you pick vials and canes out of a vessel without putting your hands into the vapour, and with a phase separator you fill equipment with liquid rather than vapour. This lets you work accurately and safely.
Our range consists of handling tools, transport aids and personal protection. Below you will find the function and application for each group.
Transport of LN2 cylinders: with a trolley or roller base you move an LN2 cylinder safely and without lifting. The roller base keeps the cylinder stable and upright and protects the floor, while the trolley makes it easier to move over thresholds.
Transfer hoses and phase separators: with flexible LN2 hoses you draw liquid nitrogen from a cylinder in a controlled way. A phase separator separates the liquid from the vapour, so you fill equipment and vessels with pure liquid instead of spattering gas bubbles.
Cryo tongs: with a pair of cryo tongs such as the CT-300 you pick vials, canes and cassettes out of a vessel without exposing your hands to the cold. The long handle keeps distance between your hand and the liquid nitrogen.
Personal protection: cryo gloves, aprons and face protection shield the skin and eyes from extreme cold and splashes. The gloves are loose-fitting, so you can remove them quickly if they come into contact with LN2.
Cryo vials and identification: cryo vials store samples at very low temperature, and with a colour-coding set and Locator retrieval tools you keep an overview and take the right samples out of storage quickly.
In cryogenic storage everything depends on traceability. Cryo vials are built to withstand temperatures down to minus 196 degrees Celsius and seal leak-free. With a colour-coding set you give vials, canes and racks a fixed colour scheme, so you keep research lines or patients apart. The Locator retrieval tools help you lift the right sample out of a vessel quickly and with minimal exposure to the vapour. This limits the time samples spend outside storage and keeps the cold chain intact. You will find matching racks and boxes among our cryo accessories.
These tools and protective items are used wherever liquid nitrogen and cryogenic storage are involved.
Biobanks and biotech: safely filling, moving and removing samples during the long-term storage of cells, tissue and DNA in liquid nitrogen.
Pharmaceutical industry: the protected handling of sensitive substances and cell banks within pharmaceutical processes, where reproducibility and safety are central.
IVF and clinical laboratories: the accurate and safe removal of cryo vials with embryos, oocytes or sperm, with minimal exposure and reliable identification.
Universities and research institutes: research that involves working with LN2 daily, where safe handling is essential for people and samples alike.
Besides supplying cryo tools and protection, Poly Temp Scientific provides installation and periodic maintenance. Our specialists advise you on the right protection, tools and accessories for your application. If you are looking for the vessels and tanks themselves, see our cryogenic storage. For advice or a quotation, please contact us. You can read more about the manufacturer on our Thermo Scientific brand page.
When working with LN2 you wear cryo gloves, face protection or safety goggles and, where needed, an apron. Liquid nitrogen has a temperature of about minus 196 degrees Celsius, so unprotected contact or splashing liquid causes immediate cold injury. Also ensure good ventilation, because evaporating nitrogen can displace oxygen.
With a pair of cryo tongs such as the CT-300 you pick vials, canes and cassettes out of a cryogenic vessel without putting your hands into the cold vapour or liquid. The long handle keeps distance between your hand and the liquid nitrogen, so you remove samples safely and accurately.
A phase separator separates the liquid nitrogen from the gas phase during transfer. This lets you fill equipment and vessels with pure liquid instead of spattering gas bubbles, which makes filling calmer, more accurate and safer.
Use a trolley or a roller base matched to the cylinder. The roller base keeps the cylinder stable and upright and lets you roll it without lifting, while a trolley makes it easier to cross thresholds. This prevents tipping and lifting injuries.
No. Ordinary gloves offer no protection against the extreme cold and can freeze to the skin on contact. Use dedicated cryo gloves that fit loosely, so you can remove them quickly if they come into contact with LN2. They are meant for brief contact and splashes, not for immersion.
With a colour-coding set you give vials, canes and racks a fixed colour scheme. This lets you keep research lines, projects or patients apart in storage and find the right sample faster, which limits the time samples spend outside cold storage.
Yes. We advise on the right tools and protection for your application, supply the range and, where needed, provide installation and periodic maintenance of your cryogenic storage. Our specialists work throughout the Netherlands. Contact us for a no-obligation consultation or a quotation.