Savant SpeedVac vacuum concentrators remove solvents from your sample volumes without overheating or boiling over your samples. These centrifugal vacuum concentrators combine centrifugal force, vacuum and controlled heat, so your samples stay intact and ready for analysis. The range runs from compact integrated models with a built-in pump and cold trap for DNA and RNA work to modular high-capacity systems that withstand aggressive solvents. Whether you evaporate a few DNA tubes or concentrate hundreds of samples daily, there is a Savant SpeedVac that fits your laboratory workflow. On this page you will find every Savant SpeedVac vacuum concentrator with specifications and pricing, plus a selection guide to match the right model to your application.

Showing all 9 results

What is a Savant SpeedVac vacuum concentrator?
A Savant SpeedVac vacuum concentrator is a centrifugal vacuum concentrator that evaporates solvents from your sample volumes. The instrument combines three principles: centrifugal force keeps the sample at the bottom of the tube and prevents bumping or boiling over, vacuum lowers the boiling point of the solvent, and controlled heat accelerates evaporation. The result is that the solvent evaporates in a controlled way while your sample stays intact and ready for analysis. This combination makes the Savant SpeedVac the standard for sample concentration of DNA, RNA, peptides and other sensitive preparations.
How does a centrifugal vacuum concentrator work?
The rotor spins your tubes while a vacuum pump lowers the pressure in the chamber. The lower pressure reduces the boiling point, so solvents such as water, ethanol or acetonitrile evaporate at a lower temperature. Centrifugal force presses the sample to the bottom of the tube, preventing bumping and keeping the sample from splashing out. Optional or built-in heat speeds the process further. The evaporated vapor is captured in a cold trap or vapor trap before it reaches the pump. This keeps your pump clean and concentrates your samples quickly and reproducibly.
Integrated and modular systems
Savant SpeedVac vacuum concentrators come in two setups. In an integrated system the concentrator, vacuum pump and cold trap sit in one compact unit, ready to use. This is ideal for laboratories that want to start DNA and RNA work quickly and have little bench space. In a modular system you choose the concentrator, pump and vapor trap separately, so you tune the system to the capacity and chemical resistance your solvents require. Modular systems handle larger tube counts and resist aggressive chemistry such as strong acids better.

Savant SpeedVac DNA130: compact model for 36 tubes, ideal for DNA and RNA applications.
Savant SpeedVac SPD120, SPD130 and SPD140: modular concentrators for up to 120 tubes of 1.5 ml for daily routine work.
Savant SpeedVac SPD210: high-capacity system for larger batches and demanding solvents.
Savant SpeedVac SPD300: large-capacity model for up to 200 tubes for high-throughput laboratories.
Savant SpeedVac SPD1030 and SPD2030: integrated systems with a built-in pump and cold trap for immediate use.
Savant SpeedVac SRF110: refrigerated vacuum concentrator for heat-sensitive samples.

Why choose a refrigerated vacuum concentrator?
Some samples, such as proteins, enzymes and RNA, are sensitive to heat and degrade at high temperatures. The refrigerated Savant SpeedVac SRF110 keeps your samples cool during concentration, so you evaporate them without losing activity or integrity. Choose a refrigerated vacuum concentrator when you process heat-sensitive preparations or when low-temperature reproducibility is critical for your analysis.
Which model should you choose?
The models differ mainly in capacity and in resistance to aggressive chemistry. For occasional DNA and RNA work a compact model such as the DNA130 is sufficient. For daily routine work with many tubes choose a modular SPD series, and for high-throughput or aggressive solvents look at the SPD210 or SPD300. If you work with heat-sensitive samples, the refrigerated SRF110 is the right choice. Unsure? Consult our selection guide, which matches the right model to your application and solvent. Every Savant SpeedVac vacuum concentrator on this page has a price, so you order directly through the product page.
See alsoBesides the concentrator, a complete Savant SpeedVac system needs a vapor collector and a vacuum source. So also view the Vapor traps for capturing solvent vapor and the Universal vacuum systems for the vacuum source. Back to the overview? Go to Savant SpeedVac.
See alsoDiscover our other Savant SpeedVac categories: all Savant SpeedVac, Vapor traps, Universal vacuum systems and Rotors & accessories.

Frequently asked questions about vacuum concentrators

What is a Savant SpeedVac vacuum concentrator?A Savant SpeedVac vacuum concentrator is a centrifugal vacuum concentrator that evaporates solvents from your samples by combining centrifugal force, vacuum and controlled heat. Your samples stay intact and ready for analysis.

How does a centrifugal vacuum concentrator work?The rotor spins your tubes while a vacuum pump lowers the solvent boiling point and heat accelerates evaporation. Centrifugal force keeps the sample at the bottom of the tube, so no bumping or loss occurs.

What is the difference between an integrated and a modular system?An integrated system, such as the SPD1030 and SPD2030, has the pump and cold trap built in and is ready to use immediately. A modular system is assembled from a separate concentrator, pump and vapor trap, giving you more capacity and better resistance to aggressive chemistry.

Which Savant SpeedVac model suits my application?That depends on your sample count and your solvents. For DNA and RNA work the compact DNA130 is sufficient, for routine work choose an SPD series, and for high-throughput or aggressive chemistry the SPD210 or SPD300. Consult our selection guide for advice per application.

Why would I choose a refrigerated vacuum concentrator?Heat-sensitive samples such as proteins, enzymes and RNA can degrade at high temperatures. The refrigerated SRF110 keeps your samples cool during evaporation, so activity and integrity are preserved.

Do I also need a vapor trap or vacuum system?Yes, a complete system needs a vapor collector and a vacuum source. View our Vapor traps for capturing solvent vapor and the Universal vacuum systems for the vacuum source, both under Savant SpeedVac.