Thermo Scientific Digital Heating Cooling Drybath

Article no.: 88880030Delivery timeiFor the current delivery time, please contact us by phone at +31 515 575 105 or send us an email at [email protected].

A programmable drybath for heating and cooling samples in compatible tubes. PID control, interchangeable blocks and ten program memories support multi-step temperature workflows on a single laboratory workstation.

4-95°C setting range; cooling depends on ambient conditions
10 programs with up to 10 steps each
PID control and two timer-start modes
Interchangeable blocks for different tube formats
230 V, 50/60 Hz; blocks ordered separately
40+ years of expertise In-house service team Fast delivery in the Netherlands

Description

Heating and cooling without a water bath

The Digital Heating Cooling Drybath transfers heat through a compatible metal block. It is useful when a protocol includes cooled and heated incubation stages using suitable tubes. PID control and programmable steps support repeatable temperature sequences. Tube type, sample volume and heat transfer should be assessed against the requirements of each protocol.

Understand the cooling limit

Temperature settings cover 4 to 95°C. The operating manual describes cooling down to approximately 20°C below ambient temperature. A 4°C setting is therefore not achievable under every operating condition: room temperature, loading and tube selection matter. This is a non-shaking drybath, not a PCR thermal cycler or a refrigerated storage cabinet.

Programs and timer control

Ten program memories each provide up to ten steps. The timer can start immediately or after the target temperature has been reached. This distinction matters when the protocol specifies an incubation period at temperature. An offset function, overtemperature protection and overcurrent detection are also described in the manual.

Select a compatible block

A block is required and purchased separately. Blocks from other Thermo drybath ranges are not automatically interchangeable. The operating manual lists the following blocks for this Heating Cooling Drybath. Confirm tube shape and dimensions, especially for the two 50 mL configurations.

Block article Layout
88880129 48 × 0.5 mL
88880130 30 × 1.5 mL
88880131 15 × 15 mL
88880132 6 × 50 mL, S
88880133 6 × 50 mL, T
88880134 35 × Ø10 mm
88880135 24 × Ø12 mm
88880136 24 × Ø13 mm
88880137 20 × Ø15 mm
88880138 16 × Ø16 mm
88880139 12 × Ø18 mm
88880140 12 × Ø20 mm

The manual allows the cover to be closed with the 0.5 mL and 1.5 mL blocks. The other listed blocks require the cover to remain open. Consider this when assessing your protocol.

Request a complete configuration

Include tube manufacturer and type, sample count, target temperatures and incubation times in your enquiry. Poly Temp can quote the 230 V instrument and the relevant block as separate items. Selecting the base unit does not include every block described or shown.

SpecificationValue
Power supply230 V, 50/60 Hz
Setting range4-95°C
Cooling limit stated in manualApproximately 20°C below ambient; application dependent
Setting resolution0.1°C
Temperature stability at 37°C±0.15°C
Temperature uniformity at 37°C±0.55°C
ControlPID
Program memory10 programs × up to 10 steps
Timer1 minute to 99 hours 59 minutes
Timer startImmediately or after reaching setpoint
Shaking functionNo
Block includedNo; select separately
ProtectionOvertemperature and overcurrent
Product weight5 kg

Frequently asked questions

Can it always cool to 4°C?

No. 4°C is the minimum setting, while achievable temperature depends on ambient conditions and loading. The manual specifies cooling to approximately 20°C below ambient.

Is a block supplied with the instrument?

No. A compatible block must be ordered separately. Specify your tube format and sample count.

Can I use a block from another Thermo drybath?

Not without checking compatibility. Use blocks specified for this instrument and verify tube fit.

Does it shake samples?

No. This model heats and cools without mixing or shaking.

Can the cover always be closed?

No. The manual permits closing it with the 0.5 mL and 1.5 mL blocks. The remaining listed blocks require an open cover.