The Gram BioCompact II RF210 laboratory freezer freezes reliably between -25 and -5 °C. With 125 litres and a 595 mm width, the cabinet is compact. Moreover, the RF210 is ATEX-suitable and very energy-efficient.
The Gram BioCompact II RF210 laboratory freezer freezes reliably between -25 and -5 °C. Therefore you store samples and reagents safely. With 125 litres and a 595 mm width, the cabinet takes little floor space. Furthermore, the RF210 suits the pharmaceutical industry and medical diagnostics well.
The RF210 uses a professional finned (block) evaporator, unique in this segment. As a result, recovery time after door opening stays minimal. The Gram BioLine air guidance system distributes the cold evenly. Additionally, the Gram BioLine MPC 4.6 controller regulates precisely and monitors upper and lower limits.
The cabinet meets ATEX Cat.3 Zone 2, internally and externally. Thus placement in a potentially explosive atmosphere is permitted. The moulded PS plastic interior cleans easily. You configure the interior with:
Want to compare cooling with freezing? See our laboratory freezers or request advice via contact.
| Feature | Specification |
|---|---|
| Type | Laboratory freezer |
| Temperature range | -25 °C tot -5 °C |
| Ambient temperature | +10/+35 °C (solid door) |
| Gross capacity | 125 litres |
| Net capacity | 104 litres |
| Dimensions (W×D×H) | 595 × 640 × 801/1001 mm |
| Net weight | 46 kg |
| Maximum interior | 7 shelves, 4 drawers of 2 wire baskets |
| Controller | Gram BioLine MPC 4.6 with E-sensor and volt-free contact |
| Evaporator | Professional finned (block) evaporator |
| Air guidance | Gram BioLine air guidance system |
| Cooling capacity at -10 °C | 154 W |
| Cooling capacity at -25 °C | 156 W |
| Insulation | 50 mm HFC-free cyclopentane |
| K-value | Solid door 0.35 W/m²K |
| Interior | Moulded PS plastic |
| Refrigerant | R600a |
| Defrost | Smart defrost, automatic |
| Sound level | 37.7 dB(A) |
| Energy consumption | 1.47 kWh/24h |
| Certification | ATEX Cat.3 Zone 2 (II 3G Ex ec nC ic IIB T3 Gc), DTI 22ATEX0251X |
| Power supply | 230 V / 50 Hz |
The RF210 freezes between -25 and -5 °C. Therefore the cabinet suits samples and reagents.
The cabinet is 595 mm wide and offers 125 litres gross. Therefore the RF210 fits small rooms too.
The professional finned evaporator limits recovery time after door opening. As a result, the temperature stays stable.
Yes, the cabinet meets ATEX Cat.3 Zone 2, both internally and externally.
Very low energy consumption of 1.47 kWh per 24 hours.