Laboratory equipment, advice and maintenance
Expert advice0515 575 105

Herasafe 2030i CTS | Cell Therapy Biological Safety Cabinet

Article no.: 51033758–51033761Delivery timeiFor the current delivery time, please contact us by phone at +31 515 575 105 or send us an email at [email protected].

Class II biological safety cabinet for cell and gene therapy workflows, with CrossBeam UV-C and a CTS documentation package. Four European EN 12469 versions, 900-1800 mm. Price on request.

Full service incl. installation
Quote on request
European Class II / EN 12469 versions
CrossBeam UV-C included
CTS documentation package included
Working widths 900-1800 mm
Stand and IQ/OQ quoted separately
40+ years of expertise In-house service team Fast delivery in the Netherlands

Description

Herasafe 2030i CTS for documented cell-therapy workflows

The Thermo Scientific Herasafe 2030i CTS Series combines a Class II biological safety cabinet with additional equipment documentation for cell and gene therapy projects. CTS stands for Cell Therapy Systems. Its purpose is to support equipment selection, traceability and qualification preparation; it does not replace your risk assessment or process validation.

What is included in the CTS version?

The four European catalogue numbers below include CrossBeam UV-C and the Product Documentation Package. This provides technical documentation and applicable certificates, including unit-specific factory acceptance test and HEPA filter reports. The precise document set is confirmed with the quotation.

Airflow control and cleaning

SmartFlow Plus regulates the airflow using DC blowers. DAVe Plus monitors operation and issues alarms. The 316L stainless steel interior, hinged front and 7-inch touchscreen support daily cleaning and operation. The standard working opening is 200 mm; the larger opening is intended for loading and cleaning only. UV-C is an additional measure and does not replace a validated cleaning and disinfection procedure.

Stand, installation and IQ/OQ

The stand is not included in the cabinet catalogue number. Fixed, manually adjustable and electrically adjustable stands are available. IQ/OQ on site is an optional, separately agreed service, including availability in the Netherlands. Installation itself is not included in IQ. Poly Temp confirms installation, site testing, qualification scope and documentation before ordering.

Choose the appropriate configuration

The models on this page are European 230 V, 50/60 Hz EN 12469 versions. The US NSF/ANSI 49 CTS versions are different catalogue numbers and are not interchangeable. This CTS cabinet is not automatically a cytotoxic/DIN 12980 cabinet, an isolator or a qualified Grade A/GMP process. Biological agents, volatile chemicals, aerosols and exhaust requirements must be assessed for the intended workflow.

For the standard version without the CTS documentation package, see Herasafe 2030i.

Compare within the range

Explore the full range of Biological safety cabinets.

FeatureSpecification
Type / standardClass II, EN 12469 (European versions)
Power supply230 V, 50/60 Hz
CrossBeam UV-CIncluded
CTS Product Documentation PackageIncluded; precise document set confirmed with quotation
FiltrationH14 HEPA, EN 1822, 99.995% MPPS
Interior316L stainless steel
Control7-inch touchscreen; SmartFlow Plus / DAVe Plus
Working opening200 mm
Usable work-surface depth465 mm (excluding intake grille)
Cabinet weight / dimensionsExcluding stand; see model table
StandOrdered separately
IQ/OQOptional service; installation not included in IQ

Model specifications

Catalogue numberWorking widthCabinet W × D × H (mm)Net weight (kg)
51033758900 mm1000 × 800 × 1536170
510337591200 mm1300 × 800 × 1536200
510337601500 mm1600 × 800 × 1536230
510337611800 mm1900 × 800 × 1536280

Stand options by cabinet width

Option900 mm1200 mm1500 mm1800 mm
Fixed stand50155665501556665015566750155668
Manually adjustable stand50155688501556895015569050155691
Electrically adjustable stand50117449501093145011745050109325

Stand codes are additional items, not included in the cabinet SKU. Confirm working height, installation clearances and service connections using the final manufacturer drawing.

Official CTS brochure · Herasafe 2030i technical specifications

Frequently asked questions

How does CTS differ from the standard Herasafe 2030i?

The European CTS catalogue numbers include CrossBeam UV-C and the additional Product Documentation Package. The documentation is the main distinction; CTS is not a different biosafety class.

Does CTS mean the complete process is GMP approved?

No. The cabinet and documentation support qualification activities. Suitability, installation, cleaning and the complete process still require your own assessment and qualification.

Are a stand and IQ/OQ included?

No. Stands are separate items. IQ/OQ is an optional service agreed in the quotation, and installation is separate from IQ.

Which sizes are available?

The European series offers 900, 1200, 1500 and 1800 mm working widths: 51033758, 51033759, 51033760 and 51033761.

Can I request a complete installed configuration?

Yes. Select a width and request a quotation. Include your workflow, room dimensions, preferred stand and documentation requirements so Poly Temp can specify the complete configuration.