Hoshizaki FM flake ice machines for cooling workflows. Compare self-contained and modular versions, ice demand and installation conditions.
Hoshizaki FM flake ice machines produce loose flake ice for cooling applications. The range contains self-contained models with an integral storage bin and modular machines requiring a suitable separate bin or installation. Choose the model according to daily ice demand, peak usage and available space.
Ice production depends on ambient and incoming water temperature. For example, the FM-120KE-HC produces up to 125 kg per day at 10 °C air and water temperature, versus 105 kg at 21 °C air / 15 °C water. Its 26 kg storage bin is a separate figure from daily production. The example specifications below do not apply to the whole range.
Refrigerant, condenser cooling and connections vary by exact model. The selection includes HC and older R452-designated articles; they must not all be described as R290 units. Follow the applicable installation and cleaning instructions. A flake ice maker does not by itself supply sterile ice or establish suitability for direct patient treatment. For laboratory workflows, evaluate ice quality and handling within your own process.
These figures apply exclusively to FM-120KE-HC, not to all options in the model selector.
| Specification | FM-120KE-HC |
|---|---|
| Configuration | Self-contained, air cooled |
| Ice production at air / water temperature | 125 kg/24 h at 10 / 10 °C; 105 kg/24 h at 21 / 15 °C; 82 kg/24 h at 32 / 21 °C |
| Storage bin | 26 kg |
| Dimensions W × D × H | 640 × 600 × 711 mm; add 87–122 mm for legs |
| Net / gross weight | 66 / 76 kg |
| Power supply | Single-phase 220–240 V, 50 Hz |
| Power consumption | 0.355 kW |
| Refrigerant | R290; charge 0.1 kg |
| Ambient temperature | 5–40 °C |
| Water temperature / pressure | 5–35 °C / 0.5–8 bar |
| Included accessories | Scoop and installation kit |
| Model / catalogue number | Product weight |
|---|---|
| FM-120KE-HC | 66 kg |
| FM-60KE-HC | 49 kg |
| FM-80KE-HC | 65 kg |
| FM-120KE-50-HC | 76 kg |
| FM-150AKE-HC-SB | 63 kg |
| FM-300AKE-HC-SB | 81 kg |
| FM-480AWKE-R452-SB | 95 kg |
| FM-600AWKE-R452-SB | 107 kg |
| FM-600AKE-R452-SB | 107 kg |
| FM-750AKE-R452-SB | 133 kg |
| FM-1000AKE-R452-SB | 146 kg |
| FM-1200ALKE-R452-SB | 98 kg |
Weight of the listed product, excluding transport packaging. Separately ordered accessories and other configurations may change the total weight.
No. Daily production describes how much ice can be made under specified test conditions. Storage capacity describes how much ice the bin holds at one time. Both must match your workflow.
No. Self-contained versions have an integral bin; modular models need a suitable separate storage or installation arrangement. Confirm this for the selected article.
No. Refrigerant is model-specific. The FM-120KE-HC uses R290, but the model list also contains older R452-designated variants. Check the exact documentation and nameplate.
Do not assume that. The ice maker alone does not validate sterile ice or direct patient use. Water quality, cleaning, handling and the intended process require their own assessment.
Specify the daily and peak ice demand, ambient and water temperatures, available space, water supply and drain, and whether a storage bin is required. Include the intended cooling process.