Multifuge X Pro centrifuges with refrigerated and ventilated configurations. Archived range: contact Poly Temp for an appropriate current alternative.
This model has been taken out of production by the manufacturer. We continue to provide service, maintenance and spare parts.
For a suitable replacement, please contact us. We are happy to advise you.
The Thermo Scientific Multifuge X Pro family includes 1.6 L and 4 L laboratory centrifuges. This page retains information for an older range that Poly Temp currently lists under discontinued products. Contact us for a suitable current alternative or support with an existing instrument.
The X1/X1R models are benchtop units with capacity up to 4 × 400 mL. The X4/X4R models are 4 L benchtop units; X4F/X4FR identifies the floor-standing versions. R denotes refrigeration. Actual capacity and speed depend on the rotor, buckets, adapters and sample vessels.
X Pro uses a colour touchscreen with storage for up to 100 programs. Auto-Lock supports rotor exchange without tools. MD versions have a different intended-use designation from general laboratory models; select the exact article number according to the required application and manufacturer instructions.
Rotor compatibility must be checked for the exact centrifuge, including approved buckets, lids and adapters. A maximum RCF from one rotor is not available with every rotor. Poly Temp can use your article number, tube format and protocol to identify a suitable combination or replacement.
| Specification | Range |
|---|---|
| Capacity | Up to 4 × 400 mL (1.6 L) or 4 × 1,000 mL (4 L), rotor-dependent |
| Maximum speed | Up to 15,200 rpm with the appropriate microlitre rotor |
| Maximum RCF | Up to 25,830 × g with the appropriate 30 × 2 mL rotor; not a swing-out rotor rating |
| Format | Benchtop; F/FR models are floor-standing |
| Cooling | R/FR models refrigerated; other listed models ventilated |
| Control | Colour touchscreen, up to 100 programs |
| Rotor exchange | Auto-Lock; approved rotor combination required |
| Intended use | MD: designated IVD models; other listed versions: general laboratory use |
| Availability | Listed by Poly Temp as discontinued; replacement advice available |
| Article number | Model | Supply | Refrigerated |
|---|---|---|---|
| 75009210 | X1 Pro-MD | 100–240 V · 50/60 Hz | No |
| 75009710 | X1 Pro | 100–240 V · 50/60 Hz | No |
| 75009250 | X1R Pro-MD | 220–230 V · 50/60 Hz | Yes |
| 75009750 | X1R Pro | 220–230 V · 50/60 Hz | Yes |
| 75009500 | X4 Pro-MD | 208–240 V · 50/60 Hz | No |
| 75009900 | X4 Pro | 208–240 V · 50/60 Hz | No |
| 75009515 | X4R Pro-MD | 220–240 V · 50 Hz / 230 V · 60 Hz | Yes |
| 75009915 | X4R Pro | 220–240 V · 50 Hz / 230 V · 60 Hz | Yes |
| 75009530 | X4F Pro-MD | 208–240 V · 50/60 Hz | No |
| 75009930 | X4F Pro | 208–240 V · 50/60 Hz | No |
| 75009536 | X4FR Pro-MD | 220–240 V · 50 Hz / 230 V · 60 Hz | Yes |
| 75009936 | X4FR Pro | 220–240 V · 50 Hz / 230 V · 60 Hz | Yes |
Electrical values are taken from the manufacturer connection table. Confirm the instrument nameplate, required circuit and local installation conditions. FR is also written RF in some manual tables.
| Model / catalogue number | Product weight |
|---|---|
| 75009500 | 89 kg |
| 75009900 | 89 kg |
| 75009515 | 120 kg |
| 75009915 | 120 kg |
| 75009530 | 152 kg |
| 75009930 | 152 kg |
| 75009936 | 145 kg |
Weight of the listed product, excluding transport packaging. Separately ordered accessories and other configurations may change the total weight.
Poly Temp lists this older range as discontinued. The page remains available for identification and existing installations. Request advice on a current alternative rather than assuming an old article is immediately deliverable.
The R and FR versions are refrigerated. Non-R versions are ventilated. The article-number table distinguishes each configuration; MD does not indicate refrigeration.
No. The maximum 25,830 × g is a rotor-specific value for a suitable 30 × 2 mL rotor. Swing-out rotors and other vessels have different limits.
Do not assume a rotor is included with a bare centrifuge article. The quotation must specify the compatible rotor, buckets, lids and adapters needed for your samples.
MD identifies the manufacturer’s IVD-designated versions. General laboratory versions are not automatically interchangeable for diagnostic applications. Check the intended use and full model documentation.