Cage changing station with HEPA H14 laminar flow for safe and efficient changing of rodent cages. Animal, operator and environmental protection, electrically adjustable and fully custom built.
The n-Laf NPU cage changing station from Nordic Labtech is a cage changing station for efficient and safe changing of rodent cages. Thanks to the laminar airflow from H14 filters, a clean environment is created above the work surface that protects the animals against contamination. At the same time, the ventilated work table protects the operator against dust and allergens from the cages. In this way, this animal cage changing station combines animal, operator and environmental protection in one compact system.
The work table is electrically height adjustable, so every operator can work in an optimal, ergonomic posture. On either side of the table there are automatic cage dispensers: a stack of clean cages on one side and a stack of dirty cages on the other. This allows cage changing to run in a logical, fast movement without unnecessary lifting or turning. Behind the dispensers the rear wall is ventilated, which gives the operator extra protection against dust that is released when opening and closing the cages.
The laminar flow from the HEPA H14 filters keeps the zone above the cages clean, while the ventilated work table and rear wall extract the dust towards the operator protection. This design makes the cage changing station suitable for facilities where both the health of the animals and the safety of the staff are paramount. The latest fan and filter technology also ensures a low noise level and low energy consumption during continuous use.
The station has a standard working area of 2000 x 1400 mm, but is supplied as a custom solution tailored to your room and workflow. On request we adapt the system into an emptying station within the LAF zone, protecting the operator and the environment against dust when emptying old bedding. For extra hygiene and cleanability, a version in stainless steel AISI304 or AISI316 is optionally available. Request a no-obligation quote for a custom laminar flow solution for your animal facility.
| Specification | n-Laf NPU cage changing station |
|---|---|
| Product type | Cage changing station with laminar airflow |
| Brand | Nordic Labtech |
| Model | NPU Cage Changing Station 2000×1400 |
| Protection | Animal, operator and environment |
| Material | White powder coated steel, optionally stainless steel AISI 304 or AISI 316 |
| Worktable | With or without, fixed height or electrically elevated, optionally ventilated with process air |
| Cage dispensers | Optional |
| Exterior dimensions (W x D x H) | 2000 x 1900 x 2700 mm |
| Interior dimensions (W x D x H) | 2000 x 1400 x 2000 mm |
| Downflow velocity | Optimum 0.30 m/s, variable from 0.1 to 0.6 m/s |
| Average downflow | 0.1 to 0.6 m/s plus/minus 10 % |
| Downflow volume | Typically 3000 m3/h |
| Total exhaust air | Typically 500 m3/h |
| Main filter | HEPA H14 to EN 1822 |
| Pre-filter | G3 or G4 |
| Laminator | PETP, pressure drop max. 40 Pa at 0.5 m/s |
| Noise level | Less than 56 dB(A) at 0.30 m/s, less than 50 dB(A) at reduced speed |
| Fans | EBM or corresponding |
| Lighting | Very low energy consumption LED, min. 800 lux or more if required |
| Power supply | 230 VAC, protected with 10 A or 16 A |
| Energy consumption with clean filters | 0.4 kW |
| Type | n-Laf NPU cage changing station |
|---|---|
| Brand | Nordic Labtech |
| Application | Changing rodent cages in animal facilities |
| Standard size | 2000 x 1400 mm |
| Filter type | HEPA H14 |
| Down flow speed | 0.30 m/s (adjustable 0.1 – 0.6 m/s) |
| Downflow volume | approx. 3000 m3/h |
| Exhaust volume | approx. 500 m3/h |
| Work table | Electrically height adjustable |
| Cage dispensers | Automatic, on both sides (clean and dirty) |
| Rear wall | Ventilated for operator protection |
| Protection | Animal, operator and environment |
| Material | Stainless steel AISI304 or AISI316 optional |
| Custom design | Yes, incl. optional emptying station |
A cage changing station is used to change rodent cages efficiently and safely. The laminar airflow from the H14 filters keeps the zone above the cages clean and protects the animals, while the ventilated work table and rear wall protect the operator against dust and allergens.
Yes. The HEPA H14 laminar flow provides a clean environment above the cages for the animals, while the ventilated work table and ventilated rear wall extract the dust and thus protect the operator and the environment. The system offers animal, operator and environmental protection in one.
Yes. The cage changing station can be custom built as an emptying station in the LAF zone. This protects the operator and the environment against dust released when emptying old bedding.
The standard size is 2000 x 1400 mm, but the station is custom built and tailored to your room and workflow. A version in stainless steel AISI304 or AISI316 is optionally available for extra hygiene and cleanability.
Yes. Thanks to the latest fan and filter technology, the station operates with a low noise level and low energy consumption, even during continuous use in an animal facility.