The Thermo Scientific CLINIConic fixed-angle rotor is built for blood separation applications. In addition, it holds 30 blood tubes or 15 mL conical tubes. Moreover, the CLINIConic spins at a fixed 37 degree angle. As a result, you process a high number of tubes per run.
Furthermore, this rotor reaches up to 14,000 rpm and 22,351 x g in the C Series. This way, you achieve a fast and complete separation. In addition, the rotor accelerates fast for optimal blood separation. As a result, you shorten the turnaround of clinical runs.
Moreover, the CLINIConic offers adapters for varied blood tubes. You place 15, 10 and 5/7 mL tubes with the right adapter. In addition, both round and conical tubes fit. This way, a single rotor covers many clinical workflows.
Finally, the CLINIConic is compatible with the refrigerated Thermo Scientific C Series centrifuges. It works with the C1TR and the C1FR. In addition, Auto-Lock rotor exchange swaps the rotor with ease. As a result, you operate the rotor with great convenience.
| Property | CLINIConic |
|---|---|
| Rotor type | Fixed-angle |
| Angle | 37 degrees |
| Maximum capacity | 30 x 15 mL |
| Maximum speed | 14,000 rpm (C1TR and C1FR) |
| Maximum RCF | 22,351 x g (C1TR and C1FR) |
| Rmax | 140 mm |
| Compatible centrifuges | Thermo Scientific C1TR and C1FR |
| Application | Blood separation, clinical chemistry |
| SKU | Description |
|---|---|
| 75003623 | CLINIConic fixed-angle rotor, 30 x 15 mL, 37 degrees, Rmax 140 mm |
The Thermo Scientific CLINIConic fixed-angle rotor spins 30 x 15 mL at a 37 degree angle. In addition, it reaches up to 14,000 rpm and 22,351 x g in the C Series. It also accelerates fast for optimal blood separation. Poly Temp supplies this rotor for the C1TR and C1FR centrifuges.








The CLINIConic fits the refrigerated Thermo Scientific C Series centrifuges. It works with the C1TR and the C1FR. The rotor is not intended for the ventilated C1T.
On the C1TR and C1FR the rotor reaches 14,000 rpm and 22,351 x g. This way, you achieve a fast and complete blood separation. As a result, you shorten the turnaround.
The rotor holds 30 x 15 mL tubes at a 37 degree angle. In addition, smaller blood tubes fit with the right adapter. As a result, you process many tubes per run.
The CLINIConic suits blood separation and clinical chemistry. For example, you separate serum and plasma. In addition, the rotor accelerates fast for optimal separation.
The CLINIConic accelerates fast for optimal blood separation. This way, you reach the target speed sooner. As a result, you handle more samples per hour.
Adapters exist for 15, 10 and 5/7 mL blood tubes. In addition, both round and conical tubes fit. This way, you match the rotor to your samples.