The Thermo Scientific Hematocrit fixed-angle rotor separates 24 capillaries at a 90 degree angle. In addition, it reaches up to 13,300 rpm and 16,810 x g in the C Series. It is intended for red blood cell separations. Poly Temp supplies this rotor for the C1T, C1TR and C1FR centrifuges.
The Thermo Scientific Hematocrit fixed-angle rotor is built for capillary blood separations. In addition, it holds 24 capillaries at a 90 degree angle. Moreover, the Hematocrit rotor reaches up to 13,300 rpm and 16,810 x g in the C Series. As a result, you separate red blood cells quickly and sharply.
Furthermore, this rotor focuses on the hematocrit determination. This way, you read the red blood cell volume fraction after the run. In addition, the high g-force delivers a compact cell fraction. As a result, you shorten the turnaround of the assay.
Moreover, the rotor runs with matching capillaries and a sealing kit. This way, you work with a fixed, reliable setup. In addition, the load stays evenly distributed. As a result, the separation stays repeatable.
Finally, the Hematocrit rotor is compatible with the Thermo Scientific C Series centrifuges. It works with the C1T, the C1TR and the C1FR. In addition, Auto-Lock rotor exchange swaps the rotor with ease. As a result, you operate the rotor with great convenience.
| Property | Hematocrit rotor |
|---|---|
| Rotor type | Fixed-angle |
| Angle | 90 degrees |
| Maximum capacity | 24 capillaries |
| Maximum speed | 13,300 rpm (C1T, C1TR and C1FR) |
| Maximum RCF | 16,810 x g (C1T, C1TR and C1FR) |
| Rmax | 85 mm |
| Compatible centrifuges | Thermo Scientific C1T, C1TR and C1FR |
| Application | Red blood cell separation, hematocrit determination |
| SKU | Description |
|---|---|
| 75005733 | Hematocrit fixed-angle rotor, 24 capillaries, 90 degrees, Rmax 85 mm |
The Hematocrit rotor fits the Thermo Scientific C Series centrifuges. It works with the C1T, the C1TR and the C1FR. In addition, you swap the rotor quickly with Auto-Lock.
On the C1T, C1TR and C1FR the rotor reaches 13,300 rpm and 16,810 x g. This way, you achieve a fast capillary separation. As a result, you shorten the turnaround.
The rotor holds 24 capillaries at a 90 degree angle. This way, you process several samples per run. As a result, you keep a good throughput.
The Hematocrit rotor suits red blood cell separations. This way, you determine the hematocrit value after the run. In addition, the high g-force delivers a compact cell fraction.
The rotor uses matching capillaries and a sealing kit. This way, you work with a fixed, reliable setup. As a result, the separation stays repeatable.
The 90 degree angle stands the capillaries upright. This way, you read the cell fraction cleanly. As a result, you get a reliable hematocrit value.