The Thermo Scientific Lindberg Blue M 1200 °C tube furnace controller is a fully wired control module with advanced microprocessor-based digital control, designed for use with Lindberg Blue M 1200 °C split-hinge tube furnaces. As a result, this independent architecture provides flexible installation: the controller can be positioned next to the tube furnace, or remote for applications in fume hoods or containment areas. Specifically, each model features a solid state power module, ON/OFF circuit breaker, and thermocouple input jacks per zone. Furthermore, twelve models are available depending on the type of tube furnace, control complexity, and required options.
Specifically, this product is a separate control module, not a complete tube furnace. As a result, the unit requires a matching Lindberg Blue M 1200 °C split-hinge tube furnace to function. Furthermore, the controller must be precisely matched to the tube furnace type: single zone models work with the CC58114 series, while three zone models require the CC58434 or CC584343 series. In addition, the interconnecting wiring between controller and tube furnace is ordered separately.
Specifically, you choose from three levels of control complexity:
Specifically, the tube furnace type determines which controller fits:
Furthermore, both three zone series carry 70 A current at 208/240V, required for the higher power of three zone tube furnaces.
Specifically, models with “B” or “PB” in the suffix feature OTC (over-temperature control). As a result, OTC acts as a backup to the main controller: an independent thermocouple and secondary control module can override the main controller and shut off power when the high limit is reached. Furthermore, OTC requires manual reset after an event, which prevents unintended restart. Notably, OTC operates via magnetic contact, driven by an independent thermocouple.
Moreover, models with “COMC” or “COMA” in the suffix feature an RS-485 communications port. Specifically, this port provides two-way communications between controller and remote computer, suited for remote monitoring and data logging. As a result, you can connect up to 30 controllers to a single PC. Furthermore, the port has 9-pin connections. In addition, Thermo Fisher does not provide software or software support: recommended suppliers are Eurotherm (itools software) and SpecView.
Specifically, the combination of tube furnace and controller determines which SKU fits your setup:
Each tube furnace controller ships with a fully wired control console featuring advanced microprocessor-based digital control, solid state power module, ON/OFF circuit breaker, and thermocouple input jacks per zone (one for single zone models, three for three zone models). As a result, the controller is immediately ready for installation. However, a power cord, hardwiring, and interconnecting wiring to the tube furnace are not included. Specifically, these must be ordered separately, plus installation by a qualified technician.
Note: this controller only works in combination with a matching Lindberg Blue M 1200 °C split-hinge tube furnace. Specifically, first determine the correct tube furnace, then choose the matching controller based on control complexity and required options.
| Feature | Specification |
|---|---|
| Type | Independent tube furnace controller |
| Compatible with | Lindberg Blue M 1200 °C split-hinge tube furnaces (HTF55322A/C, HTF55342C, HTF55347C, HTF55667C) |
| Temperature range | 100 to 1200 °C |
| Control type | Advanced microprocessor-based digital control |
| Power module | Solid state power module |
| Circuit breaker | ON/OFF circuit breaker |
| Thermocouple input | 1 jack (single zone) or 3 jacks (three zone) |
| Control options | Single program 8 segments or 5 programs 16 segments |
| Three zone modes | Mimic mode (CC58434) or independent control (CC584343) |
| Optional OTC | Available on B and PB suffix models, with manual reset |
| Optional communications | RS-485 on COMC and COMA suffix models, 9-pin connection |
| Power cord | Not included |
| Interconnecting wiring | Not included |
| Hardwiring | Required, by qualified technician |
| Certification | UL, CE |
| SKU | Control | OTC | Comm port | Voltage | Current | For tube furnace |
|---|---|---|---|---|---|---|
| CC58114A-1 | Single program 8 segments | No | No | 120V | 30 A | HTF55322A |
| CC58114C-1 | Single program 8 segments | No | No | 208/240V | 30 A | HTF55322C, HTF55342C |
| CC58114PBA-1 | 5 programs, 16 segments | Yes | No | 120V | 30 A | HTF55322A |
| CC58114PBCOMA-1 | 5 programs, 16 segments | Yes | Yes (RS-485) | 120V | 30 A | HTF55322A |
| CC58114PBC-1 | 5 programs, 16 segments | Yes | No | 208/240V | 30 A | HTF55322C, HTF55342C |
| CC58114PBCOMC-1 | 5 programs, 16 segments | Yes | Yes (RS-485) | 208/240V | 30 A | HTF55322C, HTF55342C |
| SKU | Control | Mode | OTC | Comm port | Voltage | Current |
|---|---|---|---|---|---|---|
| CC58434BC-1 | Single program 8 segments | Mimic | Yes | No | 208/240V | 70 A |
| CC58434BCOMC-1 | Single program 8 segments | Mimic | Yes | Yes (RS-485) | 208/240V | 70 A |
| CC58434PBC-1 | 5 programs, 16 segments | Mimic | Yes | No | 208/240V | 70 A |
| CC58434PBCOMC-1 | 5 programs, 16 segments | Mimic | Yes | Yes (RS-485) | 208/240V | 70 A |
| CC584343PBC-1 | 5 programs, 16 segments | Independent | Yes | No | 208/240V | 70 A |
| CC584343PBCOMC-1 | 5 programs, 16 segments | Independent | Yes | Yes (RS-485) | 208/240V | 70 A |
The Thermo Scientific Lindberg Blue M 1200 °C tube furnace controller is an independent control module ordered separately with Lindberg Blue M 1200 °C split-hinge tube furnaces. Specifically, you choose from twelve models depending on your tube furnace (single zone or three zone), required control complexity, and voltage. Furthermore, selected models offer optional OTC over-temperature control as backup, plus RS-485 communications for remote monitoring. In addition, the controller can be positioned next to the tube furnace or remote, for example in fume hoods for added operator safety.








No, this product is a separate control module, not a complete tube furnace. Specifically, the controller requires a matching Lindberg Blue M 1200 °C split-hinge tube furnace to function. As a result, you order the controller alongside your tube furnace, or as an upgrade to an existing system. Furthermore, you must choose the correct model based on the type of tube furnace (single zone or three zone) and voltage (120V or 208/240V).
Specifically, the tube furnace model determines which controller fits. For HTF55322A you need a 120V single zone controller (CC58114A series). By contrast, HTF55322C and HTF55342C work with 208/240V single zone controllers (CC58114C series). Furthermore, HTF55347C and HTF55667C require a three zone controller, available in mimic mode (CC58434 series) or fully independent control (CC584343 series). In addition, your process determines the control complexity: single program 8 segments or programmable 5 programs 16 segments.
In mimic mode (CC58434 series), the center zone is driven by a programmable controller, while the end zones follow the center zone at an adjustable deviation of maximum ± 50 °C. By contrast, in independent control (CC584343 series), each zone has its own programmable controller. As a result, mimic mode lets you easily set a gradient around the center zone, while independent control offers complete freedom to run fully different profiles per zone.
OTC (over-temperature control) is available on models with “B” or “PB” in the suffix. Specifically, OTC adds a second independent thermocouple and secondary control module that can override the main controller when the high limit is exceeded. As a result, OTC provides a backup protection layer, even when the main controller fails itself. Furthermore, OTC requires manual reset after an event, which prevents unintended restart.
For installation, in addition to the controller itself, you need: a power cord, interconnecting wiring to the tube furnace, plus hardwiring to the electrical installation. Specifically, these components are not included and must be ordered separately. As a result, installation by a qualified technician is required, especially due to the high current ratings: 30 A for single zone controllers and 70 A for three zone controllers.