The Thermo Scientific T29-8×50 is the fastest fixed-angle rotor in the LYNX series. This titanium rotor spins up to 29,000 rpm and reaches 100,605 x g. It processes 8 x 50 mL samples with the highest RCF in the portfolio. Ideal for demanding high-speed separations.
The Thermo Scientific T29-8×50 fixed-angle rotor is a titanium rotor for 8 x 50 mL tubes. Moreover, it delivers the highest RCF in the entire LYNX portfolio. In addition, the T29-8×50 reaches a maximum speed of 29,000 rpm and an RCF of 100,605 x g on the LYNX 6000. As a result, you process demanding samples with unmatched centrifugal force.
Furthermore, the titanium makes the T29-8×50 exceptionally strong. In addition, titanium easily withstands the extreme load up to 100,605 x g. This way, the rotor stays reliable at the highest RCF in the portfolio. It also performs strongly at low temperature thanks to the GreenCool technology.
In addition, you benefit from the Auto-Lock and Auto-ID technology of the LYNX platforms. This way, you exchange the rotor in seconds without tools. Moreover, the centrifuge identifies the rotor instantly and loads the correct parameters. As a result, you prevent overspeeding and work more safely.
Finally, the T29-8×50 is compatible with the Thermo Scientific LYNX 4000 and LYNX 6000 Superspeed centrifuges. On the LYNX 4000, the rotor performs at 24,000 rpm and 68,905 x g. Furthermore, the rotor suits applications in genomics, proteomics, virus research and drug discovery. This way, you get a versatile rotor for the most demanding separations.
| Property | T29-8×50 |
|---|---|
| Rotor type | Fixed-angle, titanium |
| Maximum capacity | 8 x 50 mL |
| Maximum speed | 29,000 rpm (LYNX 6000) / 24,000 rpm (LYNX 4000) |
| Maximum RCF | 100,605 x g (LYNX 6000) / 68,905 x g (LYNX 4000) |
| Rmax | 107 mm |
| Compatible centrifuges | Thermo Scientific LYNX 4000 and LYNX 6000 Superspeed |
| Material | Titanium |
| Application | High-speed separations at highest RCF, genomics, proteomics, virus research, drug discovery |
| SKU | Description |
|---|---|
| 75003009 | Thermo Scientific T29-8×50 fixed-angle rotor, 8 x 50 mL, titanium, up to 29,000 rpm and 100,605 x g |
The T29-8×50 works with the Thermo Scientific LYNX 4000 and LYNX 6000 Superspeed centrifuges. Moreover, the rotor reaches its highest RCF of 100,605 x g only on the LYNX 6000.
On the LYNX 6000, the rotor spins up to 29,000 rpm and 100,605 x g. In addition, on the LYNX 4000 it reaches a speed of 24,000 rpm and an RCF of 68,905 x g.
The T29-8×50 processes 8 x 50 mL tubes per run. This way, you combine a compact capacity with the highest RCF in the portfolio.
The T29-8×50 is a titanium fixed-angle rotor. Moreover, titanium makes the rotor exceptionally strong. This way, it easily withstands the highest RCF up to 100,605 x g.
The rotor suits demanding high-speed separations. Furthermore, it is ideal for genomics, proteomics, virus research and drug discovery.
The T29-8×50 delivers the highest RCF in the entire portfolio: 100,605 x g. Moreover, the rotor uses the full speed of 29,000 rpm on the LYNX 6000.