Description

Large muffle furnace 14 liter up to 1200 °C with four heating elements

The Thermo Scientific Thermolyne premium large muffle furnace combines a spacious 14 liter working chamber with advanced temperature control up to 1200 °C. As a result, this model suits laboratories that need both larger sample volumes and high temperature precision. Specifically, stability is ± 0.3 °C and uniformity is ± 2.2 °C at 1000 °C, considerably more accurate than smaller benchtop variants. Furthermore, built-in safety systems and a Platinel II thermocouple ensure reliable performance during extended operation at high temperatures.

Four heating elements for superior uniformity

The most distinctive feature of this large muffle furnace is the four-heating-element configuration. Specifically, elements are placed on the top, bottom, and sides of the chamber, rather than only on the sidewalls as in simpler models. As a result, heat distributes evenly across the entire sample volume, with uniformity of ± 2.2 °C at 1000 °C. Notably, this configuration prevents hotspots and cold zones, which is critical for gravimetric analysis and reproducible thermal treatments.

Three controller choices for your process

Specifically, you choose from three PID microprocessor controllers depending on the complexity of your application:

  • F6020C-33 (B1): Single setpoint with ramp to setpoint and dwell function. Specifically suitable for controlled heatup curves with a hold period. Includes mechanical OTP relay for over-temperature protection.
  • F6020C-33-80 (C1): Programmable with 1 stored program of 8 segments, including OTP relay. As a result, more complex thermal profiles become possible, for example stepwise heating followed by controlled cooldown.
  • F6030CM-33 (D1): Programmable with 5 stored programs of 16 segments each, plus RS-232 communications and OTP relay. In addition, suitable for labs that want to log data or remotely monitor from a PC.

Furthermore, all three models feature a Platinel II thermocouple, suited for extended operation at temperatures up to 1400 °C.

Applications in lab and industry

Specifically, this large muffle furnace is found in laboratories working with larger sample volumes or processing multiple samples at once. Common applications include:

  • Gravimetric analysis and ashing of larger samples
  • Sintering and bonding processes for ceramics, metal, and glass
  • Heat treatment, annealing, and tempering of metal
  • Pyrolysis and thermal decomposition
  • Calibration and crystal growth
  • Thermal expansion and viscosity testing

In addition, this model is used in pharmaceutical development, materials research, and the food industry for combustion analysis of additives and residues.

Safety and operation

Moreover, this large muffle furnace features multiple safety layers. Specifically, the door switch interrupts power to the heating elements when the door opens. Furthermore, thermocouple break protection cuts heating when a sensor fails, which prevents uncontrolled temperature rise. Notably, the mechanical OTP relay provides an independent layer of overheating protection. In addition, the built-in vent port removes fumes and moisture directly, extending the life of elements and the unit. Specifically, a 0.8 cm diameter port at the rear allows independent temperature measurement.

Standard and optional accessories

Each premium large muffle furnace ships with a Platinel II thermocouple, mechanical OTP relay, and hearth tray. As a result, the unit is immediately ready for applications up to 1200 °C without additional investment. Furthermore, a stainless steel shelf is optionally available (SH408X1, rated up to 900 °C), which doubles load capacity by allowing two sample levels. In addition, a set of hearth trays (PHX1, up to 9 pieces in a 3 × 3 pattern) and a stainless steel exhaust kit (AY408X1A, 2.5 inch ID, 5 ft length) are available.

Note: all EU models require hardwiring by a qualified technician. Specifically, no plug or power cord is supplied, because the 4400 W power demands a fixed electrical connection.

Specifications

Feature Specification
Type Premium large muffle furnace
Capacity 14 liter (0.5 cu. ft.)
Temperature range 100 to 1200 °C
Stability at 1000 °C ± 0.3 °C
Uniformity at 1000 °C ± 2.2 °C
Heating elements Four elements, top, bottom, and sides
Thermocouple Platinel II (rated up to 1400 °C)
Safety Door switch, thermocouple break protection, mechanical OTP relay
Vent port Built-in for fume and moisture removal
Monitoring port 0.8 cm diameter, rear of chamber
Voltage 240V, 50/60 Hz
Power 4400 W
Current 18.3 A
Connection No plug, requires hardwiring by a technician
Certification CE
Interior dimensions (W × D × H) 33 × 25 × 18 cm
Exterior dimensions (W × D × H) 48.5 × 51 × 53.3 cm
Shipping weight 60.8 kg
Included as standard Platinel II thermocouple, mechanical OTP relay, hearth tray
Optional accessories Stainless steel shelf SH408X1 (up to 900 °C), hearth tray set PHX1, stainless steel exhaust kit AY408X1A

Model overview

SKU Controller Programs OTP relay RS-232
F6020C-33 Single setpoint with ramp (B1) None Yes No
F6020C-33-80 Programmable (C1) 1 program, 8 segments Yes No
F6030CM-33 Programmable (D1) 5 programs, 16 segments Yes Yes

Thermo Scientific Thermolyne Premium Large Muffle Furnace

Article no.: F6020C-33Delivery timeiFor the current delivery time, please contact us by phone at +31 515 575 105 or send us an email at info@polytemp.com.

The Thermo Scientific Thermolyne premium large muffle furnace provides a 14 liter working chamber for laboratories handling larger sample volumes up to 1200 °C. Specifically, four heating elements positioned on the top, bottom, and sides deliver excellent temperature uniformity of ± 2.2 °C at 1000 °C. Furthermore, three PID controllers are available, from single setpoint with ramp to programmable with RS-232 communications. In addition, an optional stainless steel shelf is available that doubles load capacity for applications up to 900 °C.

14 liter working chamber up to 1200 °C
Four heating elements for ± 2.2 °C uniformity
Three controller choices with OTP relay standard
Platinel II thermocouple rated up to 1400 °C
Optional stainless steel shelf doubles load capacity
📐Dimensions (L×W×H)51 × 48.5 × 53.3 cm
⚖️Weight60.8 kg
View all specifications →

What is a large muffle furnace and what are the benefits?

A large muffle furnace is a laboratory furnace with a substantial chamber capacity, in this case 14 liter, that heats samples to high temperatures inside an insulated combustion chamber. Specifically, a larger size enables treating multiple samples at once or processing larger parts. In addition, premium models such as this one deliver better temperature uniformity through multiple heating elements around the chamber.

What is the difference between this 14 liter muffle furnace and the Thermolyne benchtop 5.8 liter?

The Thermolyne benchtop muffle furnace offers 5.8 liter, while this premium large muffle furnace delivers 14 liter: nearly 2.5 times as much. Moreover, this model features four heating elements around the chamber instead of two on the sides, which results in better uniformity (± 2.2 °C versus ± 3.6 °C at 1000 °C). In addition, this model includes a Platinel II thermocouple suited for temperatures up to 1400 °C as standard, while the smaller benchtop models use a Type K thermocouple.

Which of the three controllers should I choose?

Specifically, the choice depends on your process. For applications with a controlled heatup curve and a hold period, the F6020C-33 (B1) suffices. By contrast, the F6020C-33-80 (C1) offers a programmable profile of 8 segments, ideal for applications with multiple temperature steps. Furthermore, the F6030CM-33 (D1) is the choice when you want to store 5 different programs or log data via RS-232 communications.

Why does this model require hardwiring instead of a plug?

The premium large muffle furnace operates at 4400 W, which is significantly higher than smaller models. As a result, this furnace requires a fixed electrical connection through hardwiring by a qualified technician. Specifically, no plug or power cord is supplied, because standard plugs cannot safely deliver this power level during continuous use.

Can I double the 14 liter load capacity?

Yes, with the optional stainless steel shelf (SH408X1) you create a second loading level within the same chamber. As a result, load capacity effectively doubles. In addition, it is important to know: this stainless steel shelf is rated for applications up to a maximum of 900 °C, so for higher temperatures you must fall back to a single loading level on the standard hearth tray.