Laboratory equipment, advice and maintenance
Expert advice0515 575 105

Thermo Scientific Vios iDx CR cleanroom CO₂ incubator: CTS Series

Article no.: 51036430Delivery timeiFor the current delivery time, please contact us by phone at +31 515 575 105 or send us an email at [email protected].
Year-end offers33% off

Delivery and installation included

Optional collection of your old instrument for recycling.

View offer terms

A cleanroom-compatible CO₂ incubator for cell culture workflows with additional particle-control and equipment-documentation requirements. The Vios iDx CR CTS Series offers 165 or 255 litres with stainless steel or copper interiors.

Choose delivery option

Configure accessories

Select a model to see matching accessories. Quantities apply per instrument. Options without a confirmed price can be requested in a quotation.

Optional and included. Select 1 to have your old instrument collected.

For example, delivery via stairs or with lifting equipment. We assess this in advance in your quotation.

Price on request.

Cleanroom compatibility for ISO Class 5 and GMP Grade A/B
165 or 255 litres; stainless steel or copper chamber
Sealed stainless steel exterior and external HEPA particle control
180°C Steri-Run cycle and in-chamber HEPA filtration
CTS FAT documentation included; 230 V, 50/60 Hz
40+ years of expertise In-house service team Fast delivery in the Netherlands

Description

CO₂ incubation for cleanroom workflows

Vios iDx CR is the cleanroom configuration of the Thermo Scientific iDx range. It combines controlled incubation with a sealed, brushed stainless steel exterior and a rear particle-capture system. It is intended for workflows where both culture conditions and the equipment’s contribution to room cleanliness matter, including development and scale-out of cell and gene therapy processes.

How CR differs from the standard iDx

Additional cleaning and particle-control features include IP54 protection and an external HEPA system. The manufacturer documents compatibility with ISO Class 5 and GMP Grade A/B environments. This does not qualify an entire facility or automatically make a process GMP-compliant: installation, procedures and qualification remain part of your quality strategy. For routine laboratory incubation, also compare the standard Vios iDx.

Culture conditions and chamber cleaning

THRIVE airflow, in-chamber HEPA filtration and an IR180Si CO₂ sensor support consistent incubation conditions. Humidification uses an integrated 3-litre water reservoir. The 180°C Steri-Run cycle is for decontamination of the empty incubator according to the manufacturer’s procedure. Electropolished stainless steel and copper chambers allow you to select materials appropriate to your cleaning protocol and culture workflow.

Configuration options

Only 230 V base models are listed. Factory options and separately ordered accessories are specified in your quotation, rather than being assumed to be included.

  • Optional O₂ control: 1-21% or 5-90%, selected for the required process.
  • Cell Locker configuration for 165-litre models; individual Cell Locker chambers are separate accessories.
  • CultiMaxx shelving systems for 255-litre models.
  • Model-specific stands, roller bases and stacking adapters.
  • Data integration, 4-20 mA, OPC UA and additional CO₂ control functions: specify the required configuration and integration.

Documentation and project quotation

The CTS FAT package supports equipment assessment with certificates, calibration information and technical records. Site-specific IQ/OQ, data recording and other project requirements should be agreed separately. Include required capacity, chamber material, optional O₂ control, installation arrangement and data-system requirements in your enquiry. Poly Temp can then specify the relevant configuration and accessories.

SpecificationCR 165CR 255
Nominal capacity165 L255 L
Chamber W × H × D470 × 607 × 576 mm607 × 670 × 629 mm
Shelves supplied / maximum3 / 113 / 12
Maximum load per shelf10 kg14 kg stainless steel; 10 kg copper
Chamber materialElectropolished stainless steel or copperElectropolished stainless steel or copper
External particle controlRear-mounted HEPA systemRear-mounted HEPA system
ExteriorSealed brushed stainless steel; IP54Sealed brushed stainless steel; IP54
Power supply230 V, 50/60 Hz230 V, 50/60 Hz
Incubation temperatureAmbient +3°C to 55°CAmbient +3°C to 55°C
CO₂ range0-20%0-20%
CO₂ sensorIR180SiIR180Si
Humidity at 37°CApprox. 93% RH in high-humidity modeApprox. 93% RH in high-humidity mode
Water reservoir3 L3 L
Chamber air filtrationHEPAHEPA
Air circulationTHRIVETHRIVE
Decontamination cycleSteri-Run, 180°CSteri-Run, 180°C
User interface7-inch touchscreen7-inch touchscreen

O₂ control is optional. Nominal volume is not the same as usable culture space. Performance depends on loading, settings and ambient conditions. Confirm current installation dimensions for the selected configuration.

Frequently asked questions

Which configuration suits my cleanroom?

Start with culture volume and chamber material, then assess cleaning agents, installation, particle control and qualification against your cleanroom procedures. CR differs from standard iDx and automatic-door AD models.

Is O₂ control included?

No. The listed base configurations provide CO₂ control. O₂ control must be specified as a suitable factory option.

Is Cell Locker available in both sizes?

No. The brochure describes Cell Locker for 165-litre models. CultiMaxx is an optional shelving system for 255-litre models.

Does CTS include site IQ/OQ?

The CTS FAT documentation package is included. Site-specific installation and operational qualification should be agreed separately.

Which electrical versions are offered?

The listed base models use 230 V, 50/60 Hz. The 100 V and 120 V versions are not included.