Laboratory equipment, advice and maintenance
Expert advice0515 575 105

n-Safe Class I | Microbiological Safety Cabinet

Article no.: 311 6000 0900Delivery timeiFor the current delivery time, please contact us by phone at +31 515 575 105 or send us an email at [email protected].

The n-Safe Class I is a Class I microbiological safety cabinet according to EN 12469 that protects the operator and the environment. With an inflow of 0.7 m/s and HEPA H14 exhaust filter, optionally with activated carbon filter. Available in 900 to 1800 mm working width.

Full service incl. installation
Quote on request
Configure accessories

Select a model to see matching accessories. Quantities apply per instrument. Options without a confirmed price can be requested in a quotation.

Price on request.

With hooks available in two lengths. Price on request.

Price on request.

This product is supplied including installation. Request a quotation for a tailored price, optionally extended with additional options.
Class I microbiological safety cabinet according to EN 12469
Operator and environmental protection
Inflow 0.7 m/s with HEPA H14 exhaust filter
Optional additional activated carbon filter
Available in 900 to 1800 mm working width
40+ years of expertise In-house service team Fast delivery in the Netherlands

Description

n-Safe Class I microbiological safety cabinet

Operator and environmental protection according to EN 12469

The n-Safe Class I is a Class I microbiological safety cabinet according to EN 12469. The cabinet protects the operator and the laboratory environment against the material handled inside it. A Class I cabinet does not provide product protection: the sample is not shielded from contamination in the ambient air. This makes the cabinet suitable for work that requires operator and environmental protection only, for example weighing and handling powders or working with substances where product sterility is not required.

Air is drawn in along the front opening at an inflow of 0.7 m/s (adjustable 0.7-1.0 m/s) and exhausted through a HEPA H14 exhaust filter. An additional activated carbon filter is available as an option to capture odours and vapours.

Configuration and ease of use

The n-Safe Class I is available in working widths from 900 to 1800 mm. Dimmable LED lighting up to 2000 lux provides an evenly lit work surface. The cabinet can be combined with a fixed, adjustable or electrically adjustable support stand.

If you need product protection in addition to operator protection, choose a Class II biological safety cabinet. For fully enclosed work with the highest risk classes there is the Class III safety cabinet.

Key features:

  • Class I microbiological safety cabinet according to EN 12469
  • Operator and environmental protection (no product protection)
  • Inflow 0.7 m/s, adjustable 0.7-1.0 m/s
  • HEPA H14 exhaust filter according to EN 1822, 99.999% at 0.3 µm
  • Optional additional activated carbon filter
  • Dimmable LED lighting up to 2000 lux
  • Available in 900 to 1800 mm working width
PropertySpecification
TypeClass I microbiological safety cabinet
StandardEN 12469
ProtectionOperator and environment
AirflowInflow through front opening
Inflow velocity0.7 m/s (adjustable 0.7-1.0)
Filter technologyHEPA H14 exhaust filter EN 1822, 99.999% at 0.3 µm
OptionAdditional activated carbon filter
Inflow capacity460-910 m³/h (model dependent)
Noise level46-49 dB(A) according to EN 12469
PowerFrom 90 W
LightingLED 0-2000 lux, dimmable
Front window opening200 mm (adjustable 160-330)
Mains voltage220-240 V / 50-60 Hz or 110-120 V / 50-60 Hz
Work height fixed stand800 or 900 mm (±25)
Work height adjustable700-1050 mm
Minimum doorway800 mm
 
ModelExternal dimensions excl. stand (WxDxH)Internal dimensions (WxDxH)Inflow (m³/h)Weight
n-Safe Class I 9001003 × 799 × 1329 mm900 × 520(625) × 700 mm460190 kg
n-Safe Class I 12001303 × 799 × 1329 mm1200 × 520(625) × 700 mm610220 kg
n-Safe Class I 15001603 × 799 × 1329 mm1500 × 520(625) × 700 mm760250 kg
n-Safe Class I 18001907 × 799 × 1329 mm1800 × 520(625) × 700 mm910280 kg

Specifications and availability for the 2100 mm configuration are available on request.

Adjustable airflow/opening ranges are commissioning parameters, not permission to change a validated operating setting freely. Protection depends on the selected execution, risk assessment, installation, testing and correct use.

Manufacturer brochure

Frequently asked questions

What protection does a Class I safety cabinet provide?

Operator and environmental protection according to EN 12469. A Class I cabinet does not provide product protection.

What is the difference between Class I and Class II?

Class I protects the operator and the environment only. Class II additionally protects the product through a downward, HEPA-filtered airflow.

How does the airflow work?

Air is drawn in along the front opening at an inflow of 0.7 m/s and exhausted through a HEPA H14 exhaust filter.

Can the cabinet capture odours or vapours?

Yes, optionally with an additional activated carbon filter.

Which working widths are available?

Working widths of 900, 1200, 1500 and 1800 mm.

00
Configuration and application

Select the correct version and options

The exact version is confirmed with the quotation. Safety conditions always take priority over accessories.

Application and configuration

The n-Safe Class I is intended for processes requiring operator and environmental protection but not product protection. Air is drawn into the work area and the outgoing air is treated through H14 filtration.

Protection and versions

Configurable options

GroupPossibilitiesStatus
StandFixed, manually adjustable or electricOption
WorktopOne-piece, AISI 316 and custom feed-throughsOption/project
MediaElectricity, water, vacuum and gasOption/project
FiltrationAdditional activated-carbon filterConditional
ExhaustThimble/project exhaustConditional
DocumentationIQ/OQ and customer-specific validationProject option

Technical conditions

Confirm the substance/agent, quantity, aerosols, required product protection, exhaust route and any carbon-filter capacity. An activated-carbon filter is not a generic solution for unknown gases or vapours.

Application limits

Processes in which a sterile product must remain protected, unknown chemical vapours or applications requiring Class II, triple-filter or closed containment.

Advice and quotation