40+ jaar expertise in laboratoriumapparatuur
Eigen servicedienst en onderhoud
ISO 9001 gecertificeerd

n-Safe Pro Class II safety cabinet | Nordic Labtech

Article no.: 311 1300 0600Delivery timeiFor the current delivery time, please contact us by phone at +31 515 575 105 or send us an email at info@polytemp.com.

The n-Safe Pro is a Class II safety workstation according to EN 12469. The system provides operator, product and environmental protection. The cabinet features HEPA H14 filtration and adjustable air velocities. Available in 600, 900, 1200, 1500 and 1800 mm working widths.

Full service incl. installation
Quote on request
This product is supplied including installation. Request a quotation for a tailored price, optionally extended with additional options.
Class II safety workstation according to EN 12469
HEPA H14 filtration 99.999% at 0.3 µm
Adjustable downflow and inflow
Touch display with intuitive controls
Available in 600 to 1800 mm working widths
40+ years of expertise In-house service team Fast delivery in the Netherlands

Description

n-Safe Pro Class II Safety Workstation

Operator, Product and Environmental Protection According to EN 12469

The n-Safe Pro is a Class II microbiological safety workstation according to EN 12469. The cabinet provides protection for operator, product and environment. The model is suitable for routine microbiological work. The series is designed for broad laboratory applications.

Operation is via an intuitive touch display. The work area is equipped with segmented work surfaces for easy cleaning. The side windows are frameless for optimal visibility. The front window can be fully opened for access during maintenance or cleaning.

The airflow consists of a vertical downflow of 0.28 m/s and an inflow of 0.45 m/s. Both values are adjustable within the specified ranges. The deviation is less than 8 percent. The system is equipped with HEPA H14 filters according to EN 1822 with 99.999 percent efficiency at 0.3 µm.

Key Features

  • Class II safety workstation according to EN 12469
  • Vertical downflow 0.28 m/s, adjustable 0.25–0.53 m/s
  • Inflow 0.45 m/s, adjustable 0.45–0.55 m/s
  • HEPA H14 main and exhaust filter according to EN 1822
  • Dimmable LED lighting 0–2000 lux
  • Front window opening 200 mm, adjustable 160–330 mm
  • Stand available as fixed, adjustable or electrically adjustable
Property Specification
Type Class II microbiological safety workstation
Standard EN 12469
Downflow air velocity 0.28 m/s (adjustable 0.25–0.53)
Inflow air velocity 0.45 m/s (adjustable 0.45–0.55)
Deviation < 8%
Filter technology HEPA H14 EN 1822, 99.999% at 0.3 µm
Downflow capacity 510–1010 m³/h (model dependent)
Exhaust capacity 180–580 m³/h (model dependent)
Noise level 46–50 dB(A) according to EN 12469
Power From 60 W
Lighting LED 0–2000 lux, dimmable
Mains voltage 220–240 V / 50–60 Hz or 110–120 V / 50–60 Hz
Front window opening 200 mm (adjustable 160–330 mm)
Working height fixed stand 800 or 900 mm (±25 mm)
Working height adjustable 700–1050 mm
Working height electric 750–1050 mm
Minimum clearance 730 mm (600 model), others 800 mm
 
SKU Model Outer dimensions excl. stand (W x D x H) Inner dimensions (W x D x H) Weight Downflow / Exhaust (m³/h)
311 1300 0600 n-Safe Pro 600 600 × 778 × 1375 mm 540(597) × 530(640) × 700 mm 145 kg 510 / 180
311 1300 0900 n-Safe Pro 900 1003 × 799 × 1329 mm 900 × 520(625) × 700 mm 190 kg 510 / 290
311 1300 1200 n-Safe Pro 1200 1303 × 799 × 1329 mm 1200 × 520(625) × 700 mm 220 kg 680 / 390
311 1300 1500 n-Safe Pro 1500 1603 × 799 × 1329 mm 1500 × 520(625) × 700 mm 250 kg 840 / 480
311 1300 1800 n-Safe Pro 1800 1907 × 799 × 1329 mm 1800 × 520(625) × 700 mm 280 kg 1010 / 580
311 1300 2100 n-Safe Pro 2100 Project-specific; on request On request On request On request

The weights shown are indicative. Shipping weight and the installation drawing for your configuration are available on request. Use this drawing to plan access and installation space.

Specifications and availability for project-specific configurations are provided on request. Dimensions and performance depend on the configuration; data for other models do not automatically apply.

Airflow and window opening are set for the selected configuration during commissioning. Use the cabinet in its validated operating setting. Protection depends on the configuration, risk assessment, installation, testing and correct use.

Manufacturer brochure

Frequently asked questions

What protection does the n-Safe Pro provide?

A Class II safety cabinet that protects product, operator and environment to EN 12469.

What filtration does the Pro have?

HEPA H14 filtration with 99.999% retention at 0.3 µm.

Can I adjust the airflow?

Yes, both the downflow and inflow are adjustable within the specified ranges.

Which working widths is the Pro available in?

The n-Safe Pro is available from 600 to 1800 mm working width.

How is the cabinet operated?

Via a touch display with intuitive control and dimmable LED lighting.

Does the Pro meet international standards?

Yes, it is built and tested to EN 12469 and NSF/ANSI 49.

00
Configuration and application

Select the correct version and options

The exact version is confirmed with the quotation. Safety conditions always take priority over accessories.

Application and configuration

The n-Safe Pro is a Class II biological safety cabinet for routine work, diagnostics, teaching, cell culture and general microbiology. The family offers many configurable options, but these must never change or obscure the selected protection principle.

Protection and versions

Configurable options

GroupPossibilitiesStatus
StandFixed, manually adjustable or electricOption
Worktop/materialSegmented/one-piece; AISI 304/316; cut-outsOption/project
MediaElectricity, LAN/USB, water, vacuum and gas qualitiesOption/project
UV/processIntegrated or magnetic UV-C; VHP kit; IV rails; weighing supportOption/project
MonitoringMonitor in rear wall and additional measuring provisionsOption/project
Filtration/exhaustAdditional/split HEPA, trace carbon filter, thimble, hard duct and anti-blowbackConditional
ValidationDQ, IQ/OQ and Pharma versionProject option

Technical conditions

Review risk group, aerosols, process, width, worktop, media and room conditions. Your quotation states which features belong to the base cabinet and which additional options have been selected.

Application limits

Do not automatically select for cytotoxic/CMR applications requiring triple filtration, meaningful vapour loads, radioisotopes, RG4 or closed Grade A processes.

Advice and quotation

Request an n-Safe Pro version with the required dimensions, working height, worktop, connections, UV/decontamination and documentation.