40+ jaar expertise in laboratoriumapparatuur
Service & onderhoud door gecertificeerde specialisten

Thermo Scientific Vios iDx CO2 Incubator 165 and 255 litre

Article no.: 51036153Delivery timeiFor the current delivery time, please contact us by phone at +31 515 575 105 or send us an email at info@polytemp.com.

The Thermo Scientific Vios iDx CO2 Incubator is available with 165 or 255 litre gross chamber volume. With THRIVE Active Airflow, HEPA filtration and Steri-Run sterilization, you culture sensitive cells under stable, reproducible conditions with minimal contamination risk.

Choose delivery option

Available with 165 or 255 litre gross chamber volume, matched to your throughput and floor space.
THRIVE Active Airflow ensures homogeneous growth conditions and fast recovery after door openings.
HEPA filtration reaches ISO Class 5 air quality within five minutes after a 30-second door opening.
Steri-Run high-temperature sterilization eliminates contamination with 12-log sterility assurance at 180 °C.
Choice of IR180Si or TC180 CO2 sensor and of stainless steel or 100% copper inner chamber.
40+ jaar expertise Eigen servicedienst Snelle levering NL

Description

Thermo Scientific Vios iDx CO2 Incubator for reliable cell culture

The Thermo Scientific Vios iDx CO2 Incubator delivers stable culturing conditions for sensitive cell cultures. You choose between a gross chamber volume of 165 or 255 litre, matched to your throughput and available floor space. Additionally, each model combines fast recovery after door openings with a low contamination risk. As a result, your cells grow under constant, reproducible conditions.

Two capacities, one proven platform

The 165 litre model fits ideally in laboratories with limited space and supports Cell Locker Systems for added sample protection. The 255 litre model offers more culturing capacity and accommodates CultiMaxx Shelving Systems for scale-up. Moreover, you stack two incubators with a stacking adapter kit, so you add capacity without extra floor space.

THRIVE Active Airflow for homogeneous growth

THRIVE Active Airflow technology distributes filtered, conditioned air evenly throughout the chamber. Therefore, all critical growth parameters recover within ten minutes after a 30-second door opening. Moreover, the in-chamber fan maintains a uniform temperature, CO2 concentration and humidity on every shelf.

HEPA filtration and Steri-Run sterilization

The in-chamber HEPA filtration reaches ISO Class 5 air quality within five minutes after a 30-second door opening. Subsequently, the system filters the entire chamber volume every 60 seconds. Furthermore, the Steri-Run high-temperature sterilization eliminates microbial contamination with a 12-log sterility assurance at 180 °C across all internal surfaces.

Sensors and humidity tailored to your application

You choose between the IR180Si infrared sensor with silicon MEMS technology or the TC180 sensor for everyday cell culture. The integrated, covered 3-litre water reservoir maximizes relative humidity without condensation. Thus, the chamber stays dry and you limit contamination in the water.

Operation and inner chamber of your choice

The 7-inch touchscreen displays all chamber conditions at a glance. The electromagnetic door lock protects your samples as standard. Additionally, you select the electropolished stainless steel or 100% pure copper inner chamber. Copper actively combats contamination and stays easy to clean with mild detergent and 70% ethanol.

  • Choice of 165 litre (3 standard / 11 max. shelves) or 255 litre (3 standard / 12 max. shelves)
  • Temperature range from 3 °C above ambient to 55 °C
  • CO2 range 0 to 20% with a control accuracy of plus/minus 0.1%
  • Optional O2 control for hypoxic (1 to 21%) or hyperoxic (5 to 90%) conditions
  • Front-access USB port and OPC-UA integration for remote data management

The Vios iDx CO2 Incubator fits perfectly within the pharmaceutical industry and biotech and medical diagnostics. Want to know how to clean your incubator in line with GMP? Then read our article on CO2 incubator cleaning according to GMP. For advice, get in touch via our Thermo Scientific page.

Specifications

Specification Vios iDx 165 Vios iDx 255
Gross chamber volume 165 litre (5.8 cu. ft.) 255 litre (9.0 cu. ft.)
External dimensions (w x h x d) 637 x 900 x 880 mm 774 x 969 x 934 mm
Internal dimensions (w x h x d) 470 x 607 x 576 mm 607 x 670 x 629 mm
Housing Powder-coated cold-rolled steel Powder-coated cold-rolled steel
Inner chamber Electropolished stainless steel or 100% copper Electropolished stainless steel or 100% copper
Shelf dimensions (w x d) 423 x 465 mm 560 x 500 mm
Shelves 3 standard / 11 max., perforated, adjustable 3 standard / 12 max., perforated, adjustable
Maximum load per shelf 10 kg 10 kg (copper) / 14 kg (stainless steel)
Operating weight (without accessories) 82 kg 105 kg
Temperature control plus/minus 0.1 °C plus/minus 0.1 °C
Temperature range 3 °C above ambient to 55 °C 3 °C above ambient to 55 °C
Temperature uniformity less than plus/minus 0.3 °C less than plus/minus 0.3 °C
CO2 control plus/minus 0.1% plus/minus 0.1%
CO2 range 0 to 20% 0 to 20%
O2 control (optional) plus/minus 0.1%, 1 to 21% or 5 to 90% plus/minus 0.1%, 1 to 21% or 5 to 90%
Humidity at 37 °C High approx. 93%, low approx. 90% High approx. 93%, low approx. 90%
Sterilization cycle 180 °C all internal surfaces, up to 12 hours 180 °C all internal surfaces, up to 12 hours
CO2 sensor IR180Si or TC180 IR180Si or TC180
Display 7-inch touchscreen 7-inch touchscreen
Power supply 230 V, 50/60 Hz 230 V, 50/60 Hz
Connectivity Front USB port, OPC-UA, optional 4-20 mA Front USB port, OPC-UA, optional 4-20 mA

Frequently asked questions

What is the difference between the Vios iDx 165 and 255?

The main difference is capacity: the 165 litre model is more compact and supports Cell Locker Systems, whereas the 255 litre model offers more culturing space and accommodates CultiMaxx Shelving Systems. Both models share the same proven platform.

Which CO2 sensor can I choose?

You choose between the IR180Si infrared sensor and the TC180 sensor. The IR180Si is recommended for GMP environments and studies with frequent door openings, whereas the TC180 performs excellently for everyday cell culture.

Should I choose a stainless steel or copper inner chamber?

Stainless steel reduces bacterial attachment through electropolishing and is robust. Copper actively combats contamination through oxidation and stays easy to clean. Therefore, you choose copper mainly in busy research laboratories.

How quickly does the incubator recover after a door opening?

Thanks to THRIVE Active Airflow, all critical growth parameters recover within ten minutes after a 30-second door opening. Moreover, the HEPA filtration reaches ISO Class 5 air quality within five minutes.

Can I stack the Vios iDx for extra capacity?

Yes, you stack two incubators using a stacking adapter kit and roller base. Thus, you increase culturing capacity without taking up additional floor space.

00